Sample Reports

Two products.
Two deliverables.

Start with a Site Screener report to decide whether a site is worth the spend. When it passes, take it to a Full Prefeasibility Study for site-specific LCOE, IRR and NPV. Real sites, live data, same output you get from a paid run.

2 products
Screener + Full Study
5 markets
GWA 3.0 · PVGIS · ERA5
IRENA benchmarks
Generated May 2026
Product 01

Site Screener — Sample Reports

8-axis traffic-light verdict · 10-page PDF · KILL / CAUTION / PASS

Site Screener Wind Romania
Dobrogea Plateau
44.25°N 28.60°E  ·  50 MW wind
ResourceGREEN
GridGREEN
LandGREEN
EnvironmentalGREEN
MarketGREEN
SponsorAMBER
SocialGREEN
LogisticsGREEN
Overall verdict
CAUTION
Decides whether a 50 MW wind site in Romania's best wind corridor warrants a full study — one axis flagged (WACC 10.8%), rest clear.
Site Screener Solar Romania
Giurgiu County
43.90°N 26.00°E  ·  100 MW solar
ResourceGREEN
GridGREEN
LandGREEN
EnvironmentalAMBER
MarketGREEN
SponsorAMBER
SocialGREEN
LogisticsGREEN
Overall verdict
CAUTION
Screens a 100 MW solar site in southern Romania — Natura 2000 buffer proximity and WACC drive the amber flags. Good candidate for a full study with EIA focus.
Product 02

Full Prefeasibility Study — Sample Reports

Site-specific LCOE, IRR, NPV · Wind · Solar · Hybrid

Type
Market
15 reports
AEP Analysis India
Tamil Nadu Coast
10.62°N 79.84°E  ·  50 MW  ·  Hub 120 m AGL
P50 AEP
196.4 GWh/yr
Net CF
44.8 %
P90 AEP
167.5 GWh/yr
Weibull k
2.1
Wind Resource P50 / P75 / P90 Weibull Fit LCOE Site Access Environment
AEP Analysis South Africa
Northern Cape
-28.46°S 21.27°E  ·  50 MW  ·  Hub 120 m AGL
P50 AEP
174.2 GWh/yr
Net CF
39.7 %
P90 AEP
148.6 GWh/yr
Weibull k
2.3
Wind Resource P50 / P75 / P90 Weibull Fit LCOE Site Access Environment
AEP Analysis Germany
Brandenburg
52.41°N 13.89°E  ·  30 MW  ·  Hub 140 m AGL
P50 AEP
98.1 GWh/yr
Net CF
37.3 %
P90 AEP
83.4 GWh/yr
Weibull k
1.9
Wind Resource P50 / P75 / P90 Weibull Fit LCOE Site Access Environment
AEP Analysis USA
West Texas
31.84°N -101.52°W  ·  100 MW  ·  Hub 120 m AGL
P50 AEP
378.2 GWh/yr
Net CF
43.2 %
P90 AEP
321.7 GWh/yr
Weibull k
2.2
Wind Resource P50 / P75 / P90 Weibull Fit LCOE Site Access Environment
AEP Analysis Chile
Patagonia
-48.21°S -75.60°W  ·  80 MW  ·  Hub 100 m AGL
P50 AEP
342.5 GWh/yr
Net CF
48.9 %
P90 AEP
292.8 GWh/yr
Weibull k
2.4
Wind Resource P50 / P75 / P90 Weibull Fit LCOE Site Access Environment
LCOE & Financial India
Tamil Nadu Coast
50 MW  ·  CAPEX $900/kW  ·  WACC 10.5%
LCOE
$41.2 /MWh
Project IRR
14.2 %
NPV
$18.4 M
Payback
7.1 yr
LCOE (3 scenarios) IRR / NPV Sensitivity Site Access Environment
LCOE & Financial South Africa
Northern Cape
50 MW  ·  CAPEX $950/kW  ·  WACC 12.0%
LCOE
$44.8 /MWh
Project IRR
13.1 %
NPV
$11.2 M
Payback
8.3 yr
LCOE (3 scenarios) IRR / NPV Sensitivity Site Access Environment
LCOE & Financial Germany
Brandenburg
30 MW  ·  CAPEX $1,450/kW  ·  WACC 6.5%
LCOE
$58.4 /MWh
Project IRR
9.8 %
NPV
$4.1 M
Payback
11.2 yr
LCOE (3 scenarios) IRR / NPV Sensitivity Site Access Environment
LCOE & Financial USA
West Texas
100 MW  ·  CAPEX $1,100/kW  ·  WACC 7.5%
LCOE
$38.1 /MWh
Project IRR
15.1 %
NPV
$62.4 M
Payback
6.8 yr
LCOE (3 scenarios) IRR / NPV Sensitivity Site Access Environment
LCOE & Financial Chile
Patagonia
80 MW  ·  CAPEX $1,000/kW  ·  WACC 9.5%
LCOE
$36.3 /MWh
Project IRR
16.3 %
NPV
$48.1 M
Payback
6.2 yr
LCOE (3 scenarios) IRR / NPV Sensitivity Site Access Environment
Complete Site Study India
Tamil Nadu Coast
10.62°N 79.84°E  ·  50 MW  ·  Hub 120 m AGL
P50 AEP
196.4 GWh/yr
LCOE
$41.2 /MWh
Grid connection
12.4 km
Road access
3.2 km
Environmental screening — Amber  ·  Protected area buffer
Wind Resource P-Values LCOE Financial Site Access Environment
Complete Site Study South Africa
Northern Cape
-28.46°S 21.27°E  ·  50 MW  ·  Hub 120 m AGL
P50 AEP
174.2 GWh/yr
LCOE
$44.8 /MWh
Grid connection
28.1 km
Road access
8.1 km
Environmental screening — Green  ·  No constraints detected
Wind Resource P-Values LCOE Financial Site Access Environment
Complete Site Study Germany
Brandenburg
52.41°N 13.89°E  ·  30 MW  ·  Hub 140 m AGL
P50 AEP
98.1 GWh/yr
LCOE
$58.4 /MWh
Grid connection
6.2 km
Road access
1.4 km
Environmental screening — Amber  ·  Natura 2000 proximity
Wind Resource P-Values LCOE Financial Site Access Environment
Complete Site Study USA
West Texas
31.84°N -101.52°W  ·  100 MW  ·  Hub 120 m AGL
P50 AEP
378.2 GWh/yr
LCOE
$38.1 /MWh
Grid connection
18.3 km
Road access
5.6 km
Environmental screening — Green  ·  No constraints detected
Wind Resource P-Values LCOE Financial Site Access Environment
Complete Site Study Chile
Patagonia
-48.21°S -75.60°W  ·  80 MW  ·  Hub 100 m AGL
P50 AEP
342.5 GWh/yr
LCOE
$36.3 /MWh
Grid connection
45.2 km
Road access
22.1 km
Environmental screening — Green  ·  No constraints detected
Wind Resource P-Values LCOE Financial Site Access Environment
Real assessments
Same tools, same data, same output
Screener reports and full prefeasibility studies were generated through the live preFeasibility platform using real site coordinates — not mocked or hand-crafted. Every assumption, input, and benchmark is visible inside each PDF. What you see here is exactly what your run produces.
Same data spine
Every output is traceable
Both products share the same data spine: Global Wind Atlas 3.0 and PVGIS-SARAH3 (resource), Natura 2000 / EEA (environmental), OpenStreetMap (grid & logistics), GEM (pipeline), ENTSO-E (capture prices), IRENA (benchmarks), INFORM Risk Index (social), Damodaran CRP (financing). Full data sources →
GWA 3.0 PVGIS-SARAH3 ERA5 · ECMWF Natura 2000 GEM ENTSO-E IRENA INFORM
Methodology
Built for scrutiny
8-axis screening framework, Weibull fitting, P50/P75/P90 derivation, three-scenario LCOE, IRR and NPV — all methodology is documented and published. Read the methodology →

Sample reports are indicative. Outputs must be validated through independent professional assessment before investment decisions.